Z-1571-2013 Class I Terminated

Recalled by Medtronic Neuromodulation — Minneapolis, MN

FDA device recall Z-1571-2013 was initiated by Medtronic Neuromodulation on Jun 3, 2013 and is designated Class I. Reason for recall: Medtronic is providing Healthcare Professionals with important safety information and patient management recommendations regarding the unintended delivery of drug during the priming bolus function for… The recall status is terminated (terminated May 14, 2015). Affected quantity: 261,109 total devices estimated implanted Worldwide.

Recall Details

Product Type
Devices
Report Date
Jul 3, 2013
Initiation Date
Jun 3, 2013
Termination Date
May 14, 2015
Voluntary/Mandated
Voluntary: Firm initiated
Product Quantity
261,109 total devices estimated implanted Worldwide

Product Description

Medtronic SynchroMed EL Programmable pumps, Models 8626, 8626L, 8627, 8627L, (The SynchroMed EL Pumps are supplied in 10 ml or 18 ml reservoir size.) Sterilized using ethylene oxide. Product Usage: The pump is part of an infusion system that stores and delivers a prescribed drug to a specific site. The drug is stored in the pump reservoir. Per a programmed prescription, the drug moves from the pump reservoir, through the pump tubing, catheter port, and catheter, to the infusion site. The SynchroMed II Programmable Pump is indicated when patient therapy requires the chronic infusion of the following drugs or fluids: Chronic intraspinal (epidural and intrathecal) infusion of preservative-free morphine sulfate sterile solution in the treatment of chronic intractable pain, Chronic intrathecal infusion of preservative-free ziconotide sterile solution for the management of severe chronic pain, Chronic intrathecal infusion of Lioresal Intrathecal (baclofen Injection ) in the management of serve spasticity, Chronic Intravascular Infusion of Floxuridine (FUDR) or methotrexate for the treatment of primary or metastatic cancer.

Reason for Recall

Medtronic is providing Healthcare Professionals with important safety information and patient management recommendations regarding the unintended delivery of drug during the priming bolus function for the SynchroMed implantable infusion pump. The unintended delivery of drug can contribute to patient overdose or underdose symptoms which may be clinically relevant.

Distribution Pattern

Worldwide Distribution - USA Nationwide

Code Information

all SynchroMed EL pumps

Source

Dataset
openFDA device recall enforcement reports
FDA record
This recall in openFDA (JSON)
Enforcement Report
Search FDA's Enforcement Report for Z-1571-2013
openFDA file date
Oct 23, 2026
Loaded by RegDataLab
Oct 26, 2026

These dates say when openFDA published the data file and when RegDataLab last loaded it.