J. H. Emerson Co. FDA Record

Warning letters, Form 483s, inspections, recalls and 510(k) clearances

  • No warning letters matched by name
Inspections 0 0 OAI
Recalls 0 0 Class I
Warning letters 0 None on file
510(k) clearances 25 Latest Nov 22, 2000

J. H. Emerson Co. has 0 FDA recalls, 0 inspections, 25 510(k) clearances and 0 compliance actions on record. No FDA warning letter addressed to "J. H. Emerson Co." is on file.

What these totals cover: FDA records filed under the name "J. H. Emerson Co." and its spelling variant "J. H. Emerson".

Latest 510(k)
Nov 22, 2000

Summary

Record counts and when each FDA source was last refreshed
RecordsCountLast refreshedSource as ofStatus
Recalls0Drug: Nov 25, 2026; Device: Nov 25, 2026; Food: Nov 22, 2026Drug: File dated Nov 24, 2026; Device: File dated Nov 24, 2026; Food: File dated Nov 19, 2026Current
510(k) clearances25Nov 22, 2026File dated Nov 18, 2026Current
Inspections0Nov 25, 2026Newest record Nov 20, 2026Current
Compliance actions0Nov 25, 2026Newest record Nov 19, 2026Current

Reviewing J. H. Emerson Co. as a supplier? Request a free FDA snapshot: name up to five suppliers and get a PDF of their public FDA record, with sources and dates. You do not need an API connection. Each snapshot is prepared by hand.

Check this supplier

Or check J. H. Emerson Co. yourself in Claude, Cursor or ChatGPT: get the full FDA risk summary, with inspections, warning letters, Form 483s and import alerts by site.

Get a free API key

Recent 510(k) clearances

25 510(k) clearances from Jul 13, 1981 to Nov 22, 2000. Showing the 20 most recent. View all 25 510(k) clearances

K-NumberDeviceDate
K002598EMERSON COUGH ASSIST MODEL CA-3000 W/AUTOMATIC TIMING AND MODEL CM-3000 W/MANUAL TIMINGNov 22, 2000
K920910OXYGEN POWERED RESUSCITATOR FOR CPRJan 12, 1993
K924174EMERSON IN-EXSUFFLATOR, MODELS 2-CM & 2-CANov 17, 1992
K902764EMERSON 33-AN NEGATIVE PRESSURE RESPIRATOR ALARMNov 19, 1990
K896721MODEL 7-AT TREATMENT CHAMBERJan 22, 1990
K881808EMERSON CHEST RESPIRATOR, MODEL 33-CREAug 4, 1988
K873489EMERSON DISPOS THORACIC DRAINAGE SET - 551-8000Dec 29, 1987
K87293697-D EMERSON DIMMER CONTROLSep 24, 1987
K87293797-TD EMERSON TIMER/DIMMER CONTROLSep 24, 1987
K864379EMERSON 3MV VOLUME VENTILATORDec 15, 1986
K864394EMERSON 3MV VOLUME VENTILATORDec 5, 1986
K862712EMERSON MODEL 3HV COMPACT VENTILATORSep 18, 1986
K853132EMERSON TRO/CATH TROCAR CATHETERSJan 8, 1986
K854799EMERSON MODEL 3MV-OAA ALARM MODULEDec 11, 1985
K853131THORO/CATH STRAIGHT THORACIC RIGHT ANGLESep 5, 1985
K842604EMERSON MOTION BED 6-MS & 6-MEJul 20, 1984
K842487SAMSON'S NEWBORN LUNG INFLATOR 340-1000Jul 6, 1984
K842488SAMSON 1000 ANESTHESIA CIRCUITJul 6, 1984
K832271EMERSON MODEL 3MV-AP AND 3V-AP PRESS-Sep 12, 1983
K832176NEGATIVE PRESSURE CHEST RESPIRATOR PUMPSep 12, 1983

J. H. Emerson Co. and the FDA: common questions

Has J. H. Emerson Co. received an FDA warning letter?

No FDA warning letter addressed to the name "J. H. Emerson Co." is on file. This answer covers that name only: letters addressed to a related company name or to one of its sites are listed on that name's or site's own page.

Has J. H. Emerson Co. received an FDA Form 483?

FDA has not published a Form 483 for "J. H. Emerson Co." in its reading room. FDA publishes some Form 483s, not all of them.

Need more than this page shows? Ask about J. H. Emerson Co. in Claude or ChatGPT and get every site's inspections, Form 483s, warning letters and import alerts, with a link to the FDA source for each record. The API key is free: no card.

Get a free API key

Prefer a PDF? Request a free supplier snapshot.

Is this your company or a supplier you list? Link to this FDA record from your site with a free button.

Sources: openFDA, FDA Data Dashboard, FDA.gov. Report a data issue: hello@regdatalab.com.