POLYMEDCO, INC. / POLYMEDCO CANCER DIAGNOSTIC PRODUCTS, LLC. FDA Inspection Record

FEI 1000119795 · Inspections, Form 483s, warning letters and import refusals

POLYMEDCO, INC. / POLYMEDCO CANCER DIAGNOSTIC PRODUCTS, LLC. is an FDA-registered facility (FEI 1000119795) located in CORTLANDT MANOR, NY, US. RegDataLab tracks 2 FDA inspections at this facility.

What FDA found at this site

Latest inspection
Aug 3, 2017: Voluntary Action Indicated (VAI)
Inspections on record
2 (2 VAI)
Last OAI inspection
None on record
Warning letters
None matched to this FEI. Many letters do not state an FEI: search warning letters by company name
Recalls as the recalling firm
4, latest Aug 25, 2026

A Form 483 lists an inspector's observations. OAI means FDA recommends regulatory and/or administrative action. A warning letter is FDA's formal enforcement notice. No record here does not establish that a site is safe. Check this site on FDA's Data Dashboard.

Inspections and what FDA cited

Newest first. Citations are the inspector observations FDA publishes for the inspection.

DateResultWhat FDA cited
Aug 3, 2017Voluntary Action Indicated (VAI)Investigation of device failures (21 CFR 820.198(c))
Sep 7, 2012Voluntary Action Indicated (VAI)Documented evaluation (21 CFR 820.50(a)(1))
Process control procedures, Lack of or inadequate procedures (21 CFR 820.70(a))
Documentation (21 CFR 820.100(b))
Time to report - 10 days (21 CFR 806.10(b))

Recalls

Newest first. Recalls FDA's Enforcement Report lists with this FEI as the recalling firm. The recalling firm is not always the site that made the product. Search FDA's Enforcement Report by recall number.

DateClassRecallProduct and reason
Aug 25, 2026Class IIZ-0107-2027SEDIPLAST; Model/Catalog Numbers: S-100 and S-1000;
During use of an affected tube, the operator may encounter increased resistance when inserting the pipette. The resulting pressure buildup…
Oct 6, 2025Class IIIZ-0538-2026OC-Auto FOBT-CHEK Negative Controls is the negative hemoglobin control materials designed…
A labeling error was identified on the affected product. The expiration date on the kit box label and on the vial labels incorrectly stated…
Apr 30, 2018Class IIZ-3185-2018PATHFAST Myoglobin II reagent cartridge Catalog Number: PF1111-K PATHFAST¿ NTproBNP is… and 1 more product
A pinhole caused by the laser printer in the aluminum sheet over the ALP reagent wells caused leakage through the pinhole. If the cartridge…
Feb 12, 2013Class IIZ-1059-2013Test Strips packaged in the OC-Light Manual iFOBT Kit, Catalog No. FOB50. For the… and 1 more product
The test strips in the affected product lots of the OC Light immunological fecal occult blood test are being recalled because they may not…

FDA record score

7 of 100. A count of this site's adverse public FDA records, weighted by how recent each one is. A higher number means more, or more recent, records. Each record below adds the points shown.

Counted on Nov 17, 2026, method version 1. It counts records and does not judge the site: a low number does not establish that a site is safe, and sites that FDA inspects more often can collect more points. How this is counted.

5 records behind this number
RecordDatePoints x age weightAdds
Class II recall Z-0107-2027, this FEI as the recalling firmAug 25, 20264 x 14
Inspection classified VAIAug 3, 20176 x 0.251.5
Class II recall Z-3185-2018, this FEI as the recalling firmApr 30, 20184 x 0.251
Class II recall Z-1059-2013, this FEI as the recalling firmFeb 12, 201310 years or older, so it adds no points0
Inspection classified VAISep 7, 201210 years or older, so it adds no points0

When each source was last refreshed

FDA sources behind this page and when RegDataLab last refreshed each one
RecordsLast refreshedSource as ofStatus
InspectionsNov 17, 2026Newest record Nov 9, 2026Current
Inspection citationsNov 17, 2026Newest record Nov 5, 2026Current
Compliance actions (warning letters, injunctions and other action types)Nov 2, 2026Newest record Oct 29, 2026Current
Warning letter textNov 16, 2026Newest record Nov 10, 2026Current
Recalls (Enforcement Report)Nov 17, 2026Newest record Nov 11, 2026Current
Form 483s and inspection documentsNov 17, 2026Newest record Nov 16, 2026Current
Import refusalsNov 15, 2026Newest record Nov 5, 2026Current

Reviewing POLYMEDCO, INC. / POLYMEDCO CANCER DIAGNOSTIC PRODUCTS, LLC. as a supplier? Request a free FDA snapshot: name up to five suppliers and get a PDF of their public FDA record, with sources and dates. You do not need an API connection. Each snapshot is prepared by hand.

Check this supplier

Or check POLYMEDCO, INC. / POLYMEDCO CANCER DIAGNOSTIC PRODUCTS, LLC. yourself in Claude, Cursor or ChatGPT: get the full FDA risk summary, with inspections, warning letters, Form 483s and import alerts by site.

Get a free API key

Facility details

Company
POLYMEDCO, INC. / POLYMEDCO CANCER DIAGNOSTIC PRODUCTS, LLC
Location
CORTLANDT MANOR, NY (US)
Source
device

Sources: openFDA, FDA Data Dashboard, FDA.gov. Report a data issue: hello@regdatalab.com.