ETHICON ENDO-SURGERY, INC. — FDA Facility Profile

FEI 1527736

ETHICON ENDO-SURGERY, INC. is an FDA-registered facility (FEI 1527736) located in Cincinnati, OH, US. RegDataLab tracks 8 FDA inspections at this facility.

Reviewing ETHICON ENDO-SURGERY, INC. as a supplier? Request a free FDA snapshot: name up to five suppliers and get a PDF of their public FDA record, with sources and dates. You do not need an API connection. Each snapshot is prepared by hand.

Check this supplier

Or check ETHICON ENDO-SURGERY, INC. yourself in Claude, Cursor or ChatGPT: get the full FDA risk summary, with inspections, warning letters, Form 483s and import alerts by site.

Get a free API key

What FDA found at this site

Latest inspection
Aug 4, 2023: No Action Indicated (NAI)
Inspections on record
8 (1 VAI, 7 NAI)
Last OAI inspection
None on record
Warning letters
None matched to this FEI. Many letters do not state an FEI: search warning letters by company name
Recalls as the recalling firm
26, latest Sep 11, 2025
Import refusals
10 or more

A Form 483 lists an inspector's observations. OAI means FDA recommends regulatory and/or administrative action. A warning letter is FDA's formal enforcement notice. No record here does not establish that a site is safe. Check this site on FDA's Data Dashboard.

Inspections and what FDA cited

Newest first. Citations are the inspector observations FDA publishes for the inspection.

DateResultWhat FDA cited
Aug 4, 2023No Action Indicated (NAI)No citations listed
Aug 15, 2019No Action Indicated (NAI)No citations listed
May 26, 2017No Action Indicated (NAI)No citations listed
Jun 5, 2015No Action Indicated (NAI)No citations listed
Jun 11, 2014No Action Indicated (NAI)No citations listed
Dec 8, 2011No Action Indicated (NAI)No citations listed
Aug 19, 2010Voluntary Action Indicated (VAI)No citations listed
Dec 17, 2009No Action Indicated (NAI)No citations listed

Recalls

Showing the 10 most recent of 26 recalls. Recalls FDA's Enforcement Report lists with this FEI as the recalling firm. The recalling firm is not always the site that made the product. Search FDA's Enforcement Report by recall number.

DateClassRecallProduct and reason
Sep 11, 2025Class IIZ-0147-2026ECHELON LINEAR Cutters Reload 80 mm Blue, intended for transection, resection, and/or…
The devices were shipped unsterilized.
Apr 22, 2025Class IZ-1746-2025Endopath Echelon Vascular White Reload for Advanced Placement Tip (35mm, 4 row); Product…
Firm has received an increase in reports regarding inadvertent instrument lockout during surgical procedures involving the device. If…
Dec 11, 2023Class IIZ-0834-2024ENDOPATH ECHELON 45mm RELOADS WITH GRIPPING SURFACE TECHNOLOGY (GST), ECHELON Endopath…
There is the potential for incomplete staple line formation during the firing sequence, without most or all staples, which may lead to…
Jul 20, 2021Class IIZ-2355-2021HARMONIC HD 1000i Shears (20cm Shaft Length)-indicated for soft tissue incisions when… and 1 more product
An internal component may be cracked and become lodged behind the energy button potentially resulting in continuous activation of the…
Jun 3, 2021Class IIZ-2326-2021ECHELON FLEX Powered Plus Stapler-intended for transection, resection, and/or creation of…
Mislabeled: Labeled on the package as 60mm contains 45mm devices
Nov 7, 2019Class IIZ-0656-2020Ligamax 5 mm Endoscopic Multiple Clip Applier
A potential exists that certain LIGAMAX devices within the impacted lots may have small holes in the Tyvek lidding which could result in a…
Oct 3, 2019Class IZ-0200-2020ECHELON FLEX ENDOPATH 60mm Stapler - 340mm shaft, Product Code EC60A and 3 more products
The staplers may contain an out of specification anvil component within the jaw of the device. This condition may lead to malformed…
May 15, 2019Class IIZ-1888-2019Ethicon ENSEAL X1 Curved Jaw Tissue Sealer 25cm Shaft PRODUCT CODE: NSLX125C and 2 more products
Observed reported incidence rate for harm associated with intraoperative bleeding
Apr 11, 2019Class IZ-1267-2019Curved Intraluminal Staplers, 21 mm diameter, Model CDH21A The Ethicon Endo-Surgery… and 11 more products
The staplers may have an insufficient firing stroke to break the washer and completely form staples.
Dec 7, 2018Class IIZ-0695-2019PROXIMATE¿ HCS Hemorrhoidal Circular Stapler Product Code: PPH01 PPH01: The… and 1 more product
Hemorrhoidal Circular Stapler may have been assembled without a washer, this may potentially cause bleeding or soft tissue injury during use…

Facility details

Company
Ethicon Endo-Surgery Inc
Location
Cincinnati, OH (US)
Source
device