Septodont Inc. FDA Inspection Record
Septodont Inc. is an FDA-inspected facility (FEI 1721729) located in Louisville, CO, US. RegDataLab tracks 6 FDA inspections at this facility.
What FDA found at this site
- Latest inspection
- Feb 10, 2020: No Action Indicated (NAI)
- Inspections on record
- 6 (4 VAI, 2 NAI)
- Last OAI inspection
- None on record
- Warning letters
- None matched to this FEI. Many letters do not state an FEI: search warning letters by company name
- Recalls as the recalling firm
- 3, latest May 2, 2019
Inspections and what FDA cited
| Date | Result | What FDA cited |
|---|---|---|
| Feb 10, 2020 | No Action Indicated (NAI) | No citations listed |
| Nov 22, 2017 | Voluntary Action Indicated (VAI) | Adequate lab facilities not available (21 CFR 211.22(b)) Strict control not exercised over labeling issued (21 CFR 211.125(a)) Procedure Deviations Recorded and Justified (21 CFR 211.100(b)) |
| May 19, 2014 | Voluntary Action Indicated (VAI) | Lack of or inadequate procedures (21 CFR 820.100(a)) Complaints (21 CFR 820.198(a)) |
| Jun 12, 2013 | Voluntary Action Indicated (VAI) | Authority lacking to review records, investigate errors (21 CFR 211.22(a)) Adequate lab facilities not available (21 CFR 211.22(b)) Procedures not in writing, fully followed (21 CFR 211.22(d)) Review of representative number of batches (21 CFR 211.180(e)(1)) and 2 more |
| Aug 25, 2011 | Voluntary Action Indicated (VAI) | No citations listed |
| Apr 14, 2010 | No Action Indicated (NAI) | No citations listed |
Recalls
| Date | Class | Recall | Product and reason |
|---|---|---|---|
| May 2, 2019 | Class II | D-1307-2019 | Articaine DENTAL, Articane hydrochloride 4% and epinephrine 1:100,000,
50 cartridges… Labeling: Not Elsewhere Classified. This recall has been initiated due to mislabeling. The printed carton used in manufacturing both batches… |
| Apr 13, 2018 | Class III | D-0828-2018 | OraVerse (Phentolamine Mesylate) Injection, 0.4 mg/1.7mL, packaged in a box of 10… Failed Impurities/Degradation: This recall has been initiated due to an out of specification (OOS) result that was obtained for related… |
| Jul 16, 2014 | Class II | Z-2128-2014 | Henry Schein Natural Elegance SE Bond Self-Etch Light-Cure
Adhesive contains 50 0.125 mL… and 1 more product Septodont is recalling Self-Etch bond because the material was incorrectly packaged. |
FDA record score
3 of 100. A count of this site's adverse public FDA records, weighted by how recent each one is. A higher number means more, or more recent, records. Each record below adds the points shown.
6 records behind this number
| Record | Date | Points x age weight | Adds |
|---|---|---|---|
| Inspection classified VAI | Nov 22, 2017 | 6 x 0.25 | 1.5 |
| Class II recall D-1307-2019, this FEI as the recalling firm | May 2, 2019 | 4 x 0.25 | 1 |
| Class II recall Z-2128-2014, this FEI as the recalling firm | Jul 16, 2014 | 10 years or older, so it adds no points | 0 |
| Inspection classified VAI | May 19, 2014 | 10 years or older, so it adds no points | 0 |
| Inspection classified VAI | Jun 12, 2013 | 10 years or older, so it adds no points | 0 |
| Inspection classified VAI | Aug 25, 2011 | 10 years or older, so it adds no points | 0 |
When each source was last refreshed
| Records | Last refreshed | Source as of | Status |
|---|---|---|---|
| Inspections | Nov 22, 2026 | Newest record Nov 9, 2026 | Current |
| Inspection citations | Nov 22, 2026 | Newest record Nov 5, 2026 | Current |
| Compliance actions (warning letters, injunctions and other action types) | Nov 22, 2026 | Newest record Nov 13, 2026 | Current |
| Warning letter text | Nov 22, 2026 | Newest record Nov 17, 2026 | Current |
| Recalls (Enforcement Report) | Nov 22, 2026 | Newest record Nov 18, 2026 | Current |
| Form 483s and inspection documents | Nov 18, 2026 | Newest record Nov 17, 2026 | Current |
| Import refusals | Nov 22, 2026 | Newest record Nov 12, 2026 | Current |