Battle Creek Equipment FDA Inspection Record

FEI 1833125 · Inspections, Form 483s, warning letters and import refusals

Battle Creek Equipment is an FDA-registered facility (FEI 1833125) located in Fremont, IN, US. RegDataLab tracks 8 FDA inspections and 1 compliance action at this facility.

What FDA found at this site

Latest inspection
Oct 11, 2018: No Action Indicated (NAI)
Inspections on record
8 (3 OAI, 4 VAI, 1 NAI)
Last OAI inspection
May 31, 2017
Warning letters
1 on record (posted FDA warning letters and Data Dashboard warning letters for this FEI, counted once), latest Apr 3, 2015. Many letters do not state an FEI: search warning letters by company name
Recalls as the recalling firm
1, latest Sep 15, 2016

A Form 483 lists an inspector's observations. OAI means FDA recommends regulatory and/or administrative action. A warning letter is FDA's formal enforcement notice. No record here does not establish that a site is safe. Check this site on FDA's Data Dashboard.

Inspections and what FDA cited

Newest first. Citations are the inspector observations FDA publishes for the inspection.

DateResultWhat FDA cited
Oct 11, 2018No Action Indicated (NAI)Design input - Lack of or inadequate procedures (21 CFR 820.30(c))
May 31, 2017Official Action Indicated (OAI)Design control - no procedures (21 CFR 820.30(a))
Documentation (21 CFR 820.80(e))
Nonconforming product control (21 CFR 820.90(a))
Lack of or inadequate procedures (21 CFR 820.100(a))
and 6 more
Feb 10, 2016Official Action Indicated (OAI)DHR - not or inadequately maintained (21 CFR 820.184)
Documentation (21 CFR 820.80(e))
Nonconforming product control (21 CFR 820.90(a))
Lack of or inadequate procedures (21 CFR 820.100(a))
and 4 more
Feb 12, 2015Official Action Indicated (OAI)Lack of or inadequate complaint procedures (21 CFR 820.198(a))
Design validation- Lack of or inadequate procedures (21 CFR 820.30(g))
Design changes - Lack of or Inadequate Procedures (21 CFR 820.30(i))
Documentation (21 CFR 820.75(a))
and 6 more
Aug 1, 2013Voluntary Action Indicated (VAI)No citations listed
Sep 13, 2012Voluntary Action Indicated (VAI)No citations listed
Mar 1, 2011Voluntary Action Indicated (VAI)Lack of or inadequate procedures for storage. (21 CFR 820.150)
Lack of or inadequate DHR procedures (21 CFR 820.184)
DMR - not or inadequately maintained (21 CFR 820.181)
Quality Audit/Reaudit - conducted (21 CFR 820.22)
Jan 16, 2009Voluntary Action Indicated (VAI)Product rework procedures, Lack of or inadequate procedures (21 CFR 820.90(b)(2))
Management review - Lack of or inadequate procedures (21 CFR 820.20(c))
Lack of procedures, or not maintained (21 CFR 820.40)

Warning letters

Newest first. Posted FDA warning letters and Data Dashboard warning letters for this FEI, counted once. Many letters do not state an FEI, so this list can be incomplete: search warning letters by company name.

Recalls

Newest first. Recalls FDA's Enforcement Report lists with this FEI as the recalling firm. The recalling firm is not always the site that made the product. Search FDA's Enforcement Report by recall number.

DateClassRecallProduct and reason
Sep 15, 2016Class IIZ-0349-2017Model 055: Thermophore Classic, Professional Quality, Deep-Heat Therapy, Model 055 Large…
Products manufactured with the SPT cord have a known failure mode of sparking,causing smoke, fire and burns.

FDA record score

8 of 100. A count of this site's adverse public FDA records, weighted by how recent each one is. A higher number means more, or more recent, records. Each record below adds the points shown.

Counted on Nov 28, 2026, method version 1. It counts records and does not judge the site: a low number does not establish that a site is safe, and sites that FDA inspects more often can collect more points. How this is counted.

9 records behind this number
RecordDatePoints x age weightAdds
Inspection classified OAIMay 31, 201730 x 0.257.5
Class II recall Z-0349-2017, this FEI as the recalling firmSep 15, 201610 years or older, so it adds no points0
Inspection classified OAIFeb 10, 201610 years or older, so it adds no points0
Warning letter on FDA's dashboard, which does not show close-outsApr 3, 201510 years or older, so it adds no points0
Inspection classified OAIFeb 12, 201510 years or older, so it adds no points0
Inspection classified VAIAug 1, 201310 years or older, so it adds no points0
Inspection classified VAISep 13, 201210 years or older, so it adds no points0
Inspection classified VAIMar 1, 201110 years or older, so it adds no points0
Inspection classified VAIJan 16, 200910 years or older, so it adds no points0

When each source was last refreshed

FDA sources behind this page and when RegDataLab last refreshed each one
RecordsLast refreshedSource as ofStatus
InspectionsNov 28, 2026Newest record Nov 20, 2026Current
Inspection citationsNov 28, 2026Newest record Nov 17, 2026Current
Compliance actions (warning letters, injunctions and other action types)Nov 28, 2026Newest record Nov 19, 2026Current
Warning letter textNov 28, 2026Newest record Nov 24, 2026Current
Recalls (Enforcement Report)Nov 28, 2026Newest record Nov 25, 2026Current
Form 483s and inspection documentsNov 18, 2026Newest record Nov 17, 2026Current
Import refusalsNov 22, 2026Newest record Nov 12, 2026Current

Reviewing Battle Creek Equipment as a supplier? Ask Claude with the RegDataLab connector to get every site's inspections, Form 483s, warning letters, recalls and import alerts, with FDA sources and dates. Prefer a PDF? Request a free supplier snapshot (up to five suppliers, prepared by hand).

Question to ask in Claude

Use RegDataLab to give me an FDA risk summary for Battle Creek Equipment: recent inspections and their outcomes, warning letters, recalls and import alerts by site, with source links and dates.

Ask Claude about Battle Creek Equipment → Check this supplier

Facility details

Company
Battle Creek Equipment Co.
Location
Fremont, IN (US)
Source
device

Sources: openFDA, FDA Data Dashboard, FDA.gov. Report a data issue: hello@regdatalab.com.