Kwok Shing, Inc. FDA Inspection Record

FEI 2937271 · Inspections, Form 483s, warning letters and import refusals

Kwok Shing, Inc. is an FDA-inspected facility (FEI 2937271) located in San Francisco, CA, US. RegDataLab tracks 5 FDA inspections at this facility.

What FDA found at this site

Latest inspection
Jan 15, 2020: Voluntary Action Indicated (VAI)
Inspections on record
5 (4 VAI, 1 NAI)
Last OAI inspection
None on record
Warning letters
None matched to this FEI. Many letters do not state an FEI: search warning letters by company name
Recalls as the recalling firm
2, latest Sep 8, 2026

A Form 483 lists an inspector's observations. OAI means FDA recommends regulatory and/or administrative action. A warning letter is FDA's formal enforcement notice. No record here does not establish that a site is safe. Check this site on FDA's Data Dashboard.

Inspections and what FDA cited

Newest first. Citations are the inspector observations FDA publishes for the inspection.

DateResultWhat FDA cited
Jan 15, 2020Voluntary Action Indicated (VAI)Production, process controls - implement (21 CFR 111.55)
Jan 5, 2017Voluntary Action Indicated (VAI)Sufficient space (21 CFR 110.20(b)(1))
Written procedures - holding; distributing (21 CFR 111.475(b)(1))
Written procedures - product complaint; review, investigate (21 CFR 111.570(b)(1))
Reserve sample - collect, hold (21 CFR 111.83(a))
and 3 more
Jan 5, 2017Voluntary Action Indicated (VAI)Written procedures - holding; distributing (21 CFR 111.475(b)(1))
Written procedures - product complaint; review, investigate (21 CFR 111.570(b)(1))
Production, process controls - implement (21 CFR 111.55)
Reserve sample - collect, hold (21 CFR 111.83(a))
and 1 more
Nov 19, 2013Voluntary Action Indicated (VAI)Sufficient space (21 CFR 110.20(b)(1))
Failure to clean - general (21 CFR 110.35(d))
Manufacturing conditions (21 CFR 110.80(b)(2))
May 19, 2010No Action Indicated (NAI)No citations listed

Recalls

Newest first. Recalls FDA's Enforcement Report lists with this FEI as the recalling firm. The recalling firm is not always the site that made the product. Search FDA's Enforcement Report by recall number.

DateClassRecallProduct and reason
Sep 8, 2026Class IIIH-1393-2026American Ginsengs. PRODUCT OF WISCONSIN. NET WT: 4 oz. NET WT. 8 oz.
Potential contamination with pesticides.
May 24, 2006Class IIIF-436-7PANAX RED GINSENG, One Pound, Grade 15, 'Heven' Label on the tin states : Panx Red…
FDA analysis found the following pestidide residues which are not allowed for use in ginseng: quintozene (PCNB), pentachlorophenyl methyl…

FDA record score

5 of 100. A count of this site's adverse public FDA records, weighted by how recent each one is. A higher number means more, or more recent, records. Each record below adds the points shown.

Counted on Nov 24, 2026, method version 1. It counts records and does not judge the site: a low number does not establish that a site is safe, and sites that FDA inspects more often can collect more points. How this is counted.

4 records behind this number
RecordDatePoints x age weightAdds
Inspection classified VAIJan 15, 20206 x 0.251.5
Inspection classified VAIJan 5, 20176 x 0.251.5
Inspection classified VAIJan 5, 20176 x 0.251.5
Inspection classified VAINov 19, 201310 years or older, so it adds no points0

When each source was last refreshed

FDA sources behind this page and when RegDataLab last refreshed each one
RecordsLast refreshedSource as ofStatus
InspectionsNov 24, 2026Newest record Nov 20, 2026Current
Inspection citationsNov 24, 2026Newest record Nov 17, 2026Current
Compliance actions (warning letters, injunctions and other action types)Nov 24, 2026Newest record Nov 19, 2026Current
Warning letter textNov 24, 2026Newest record Nov 17, 2026Current
Recalls (Enforcement Report)Nov 24, 2026Newest record Nov 18, 2026Current
Form 483s and inspection documentsNov 18, 2026Newest record Nov 17, 2026Current
Import refusalsNov 22, 2026Newest record Nov 12, 2026Current

Reviewing Kwok Shing, Inc. as a supplier? Request a free FDA snapshot: name up to five suppliers and get a PDF of their public FDA record, with sources and dates. You do not need an API connection. Each snapshot is prepared by hand.

Check this supplier

Or check Kwok Shing, Inc. yourself in Claude, Cursor or ChatGPT: get the full FDA risk summary, with inspections, warning letters, Form 483s and import alerts by site.

Get a free API key

Facility details

Company
Kwok Shing, Inc.
Location
San Francisco, CA (US)
Source
inspections

Sources: openFDA, FDA Data Dashboard, FDA.gov. Report a data issue: hello@regdatalab.com.