Respironics California, LLC FDA Inspection Record

FEI 3002470603 · Inspections, Form 483s, warning letters and import refusals

Respironics California, LLC (FEI 3002470603) located in Carlsbad, California, United States has FDA import refusal records.

What FDA found at this site

Inspections on record
None in FDA's published inspection data
Warning letters
None matched to this FEI. Many letters do not state an FEI: search warning letters by company name
Recalls as the recalling firm
14, latest Feb 28, 2022

A Form 483 lists an inspector's observations. OAI means FDA recommends regulatory and/or administrative action. A warning letter is FDA's formal enforcement notice. No record here does not establish that a site is safe. Check this site on FDA's Data Dashboard.

Recalls

Showing the 10 most recent of 14 recalls. Recalls FDA's Enforcement Report lists with this FEI as the recalling firm. The recalling firm is not always the site that made the product. Search FDA's Enforcement Report by recall number.

DateClassRecallProduct and reason
Feb 28, 2022Class IZ-0907-2022Philips Respironics V60 Ventilator (All Models, including: 1053613, 1053614, 1053615… and 2 more products
Ventilator units have an issue impacting an internal electrical circuit within the ventilators, that in some cases could result in the…
Jan 24, 2022Class IZ-0662-2022Philips Respironics V60 Ventilator Part Number 1053617 and 1 more product
A limited number of ventilators were assembled with expired adhesive. If the adhesive fails, a bracket may become loose and potentially…
Jun 18, 2021Class IZ-2073-2021Philips Respironics V60 Ventilator with Software Versions 3.00 and 3.10. The… and 1 more product
It has been identified that ventilators equipped with High Flow Therapy (Software Versions 3.00 and 3.10), that includes a designed safety…
Jan 6, 2021Class IIZ-1137-2021PHILIPS BATTERY, V60 14.4V, 11.0 Ah, 163 Wh, REF 1076374(1058272), LOT M94663-P1 - Product…
Due to unqualified "design verification" batteries being shipped to customers.
Oct 30, 2020Class IIZ-0885-2021Philips Respironics V60 Ventilator Part Number 1053613 - Product Usage: intended to be… and 16 more products
Ventilator may experience potential issues with the backup battery failures: 1) if the battery is allowed to over discharge, or 2) if the…
Mar 5, 2020Class IIZ-1622-2020Philips V60 Ventilators with Power Management PCBA part number 1055906
Solder connection failure on Power Management printed circuit board assembly of ventilators may cause 1) Blower to lose power, spool down…
Sep 11, 2019Class IIZ-1152-2020Respironics V60 Ventilator, Service # 850008, REF: 1053613, 1053614, 1053617, 1053614 and 3 more products
Ventilator touchscreen may become frozen and fail to respond to touch commands. If a patient requires a change in therapy, there is no…
Apr 24, 2017Class IZ-2061-2017Philips V60 Ventilators, Material No. 850008, 1053613, 1053614, 1053615, 1053616, 1053617…
Over time, low-frequency vibrations can cause the pins within the female connectors on the Motor Controller to Data Acquisition Board…
Feb 1, 2017Class IIZ-1687-2017Philips V60 Ventilator with Version 2.20 Software, Description: V 60 Ventilator,Intl…
The V60 Ventilator with Version 2.20 software installed may falsely detect that the blower motor has stalled. If this condition occurs, the…
Oct 29, 2014Class IIZ-0485-2015Esprit V1000 Ventilator and Esprit/V200 Conversion Ventilator The Esprit V1000 and…
If the power supply fan mounting screws are installed incorrectly, the ends of the screws may touch the power supply printed circuit board…

FDA record score

Not scored. FDA's published inspection data has no inspection for this site, and the score is only counted for inspected sites. This is not a score of 0. The records FDA does list for this FEI are below.

Counted on Nov 29, 2026, method version 1. How this is counted.

14 records FDA lists for this FEI
RecordDatePoints x age weightAdds
Class I recall Z-0907-2022, this FEI as the recalling firmFeb 28, 2022The site is not scored, so it adds no points0
Class I recall Z-0662-2022, this FEI as the recalling firmJan 24, 2022The site is not scored, so it adds no points0
Class I recall Z-2073-2021, this FEI as the recalling firmJun 18, 2021The site is not scored, so it adds no points0
Class I recall Z-2061-2017, this FEI as the recalling firmApr 24, 2017The site is not scored, so it adds no points0
Class II recall Z-1137-2021, this FEI as the recalling firmJan 6, 2021The site is not scored, so it adds no points0
Class II recall Z-0885-2021, this FEI as the recalling firmOct 30, 2020The site is not scored, so it adds no points0
Class II recall Z-1622-2020, this FEI as the recalling firmMar 5, 2020The site is not scored, so it adds no points0
Class II recall Z-1152-2020, this FEI as the recalling firmSep 11, 2019The site is not scored, so it adds no points0
Class II recall Z-1687-2017, this FEI as the recalling firmFeb 1, 2017The site is not scored, so it adds no points0
Class II recall Z-0485-2015, this FEI as the recalling firmOct 29, 201410 years or older, so it adds no points0
Class I recall Z-0008-2015, this FEI as the recalling firmSep 17, 201410 years or older, so it adds no points0
Class I recall Z-1537-2013, this FEI as the recalling firmJun 4, 201310 years or older, so it adds no points0
Class I recall Z-2260-2012, this FEI as the recalling firmJul 31, 201210 years or older, so it adds no points0
Class II recall Z-2084-2013, this FEI as the recalling firmOct 29, 200710 years or older, so it adds no points0

When each source was last refreshed

FDA sources behind this page and when RegDataLab last refreshed each one
RecordsLast refreshedSource as ofStatus
InspectionsNov 29, 2026Newest record Nov 20, 2026Current
Inspection citationsNov 29, 2026Newest record Nov 17, 2026Current
Compliance actions (warning letters, injunctions and other action types)Nov 29, 2026Newest record Nov 19, 2026Current
Warning letter textNov 29, 2026Newest record Nov 24, 2026Current
Recalls (Enforcement Report)Nov 28, 2026Newest record Nov 25, 2026Current
Form 483s and inspection documentsNov 18, 2026Newest record Nov 17, 2026Current
Import refusalsNov 29, 2026Newest record Nov 19, 2026Current

Reviewing Respironics California, LLC as a supplier? Ask Claude with the RegDataLab connector to get every site's inspections, Form 483s, warning letters, recalls and import alerts, with FDA sources and dates. Prefer a PDF? Request a free supplier snapshot (up to five suppliers, prepared by hand).

Question to ask in Claude

Use RegDataLab to give me an FDA risk summary for Respironics California, LLC: recent inspections and their outcomes, warning letters, recalls and import alerts by site, with source links and dates.

Ask Claude about Respironics California, LLC → Check this supplier

Facility details

Location
Carlsbad, California (United States)

Sources: openFDA, FDA Data Dashboard, FDA.gov. Report a data issue: hello@regdatalab.com.