BIOMET UK LTD. FDA Inspection Record

FEI 3002806535 · Inspections, Form 483s, warning letters and import refusals

BIOMET UK LTD. is an FDA-registered facility (FEI 3002806535) located in BRIDGEND, GB. RegDataLab tracks 3 FDA inspections at this facility.

What FDA found at this site

Latest inspection
Aug 3, 2017: Voluntary Action Indicated (VAI)
Inspections on record
3 (2 VAI, 1 NAI)
Last OAI inspection
None on record
Warning letters
None matched to this FEI. Many letters do not state an FEI: search warning letters by company name
Recalls as the recalling firm
4, latest Aug 9, 2018
Import refusals
1

A Form 483 lists an inspector's observations. OAI means FDA recommends regulatory and/or administrative action. A warning letter is FDA's formal enforcement notice. No record here does not establish that a site is safe. Check this site on FDA's Data Dashboard.

Inspections and what FDA cited

Newest first. Citations are the inspector observations FDA publishes for the inspection.

DateResultWhat FDA cited
Aug 3, 2017Voluntary Action Indicated (VAI)Lack of or inadequate complaint procedures (21 CFR 820.198(a))
Design input - Lack of or inadequate procedures (21 CFR 820.30(c))
Design validation- Lack of or inadequate procedures (21 CFR 820.30(g))
DHR content (21 CFR 820.184)
Mar 18, 2015Voluntary Action Indicated (VAI)Contamination control, Lack of or inadequate procedures (21 CFR 820.70(e))
Lack of or inadequate procedures (21 CFR 820.100(a))
Jul 2, 2009No Action Indicated (NAI)Activity documentation (21 CFR 820.70(g)(1))
Design verification - documentation (21 CFR 820.30(f))
Design validation - documentation (21 CFR 820.30(g))

Recalls

Newest first. Recalls FDA's Enforcement Report lists with this FEI as the recalling firm. The recalling firm is not always the site that made the product. Search FDA's Enforcement Report by recall number.

DateClassRecallProduct and reason
Aug 9, 2018Class IIZ-3261-2018HipLOC Hip Fracture Fixation System- Hiploc System 130¿ Plate 38 mm Barrel 4 Hole… and 3 more products
HipLOC System Plate Barrel due to an undersized bore on the HipLOC plate barrel, can result in the lag screw not fitting through the barrel
Jan 5, 2016Class IIZ-1152-2017Oxford Knee System Tibial Resector Body Tube & Guides Product Usage: Instruments for… and 23 more products
Zimmer Biomet is conducting a medical device field action for various lot-specific Oxford Knee instruments due to potential alumina…
Mar 20, 2013Class IIZ-1124-2013REF 32-422760 Oxford Uni Knee System,Toffee Hammer, non-sterile, found in REF…
Investigation of complaints found excessive use of the instrument could result in cracking on the weld between the head and the handle…
Jul 27, 2012Class IIZ-2224-2012Oxford Gap Gauge SML 3/4mm. The instrument is used for an intermediate check of the…
A drafting error during an unrelated design change has led to 4 misleading dimensions on the drawing. The CAD model remained the same…

FDA record score

3 of 100. A count of this site's adverse public FDA records, weighted by how recent each one is. A higher number means more, or more recent, records. Each record below adds the points shown.

Counted on Nov 25, 2026, method version 1. It counts records and does not judge the site: a low number does not establish that a site is safe, and sites that FDA inspects more often can collect more points. How this is counted.

6 records behind this number
RecordDatePoints x age weightAdds
Inspection classified VAIAug 3, 20176 x 0.251.5
Class II recall Z-3261-2018, this FEI as the recalling firmAug 9, 20184 x 0.251
Class II recall Z-1152-2017, this FEI as the recalling firmJan 5, 201610 years or older, so it adds no points0
Inspection classified VAIMar 18, 201510 years or older, so it adds no points0
Class II recall Z-1124-2013, this FEI as the recalling firmMar 20, 201310 years or older, so it adds no points0
Class II recall Z-2224-2012, this FEI as the recalling firmJul 27, 201210 years or older, so it adds no points0

When each source was last refreshed

FDA sources behind this page and when RegDataLab last refreshed each one
RecordsLast refreshedSource as ofStatus
InspectionsNov 25, 2026Newest record Nov 20, 2026Current
Inspection citationsNov 25, 2026Newest record Nov 17, 2026Current
Compliance actions (warning letters, injunctions and other action types)Nov 25, 2026Newest record Nov 19, 2026Current
Warning letter textNov 24, 2026Newest record Nov 17, 2026Current
Recalls (Enforcement Report)Nov 24, 2026Newest record Nov 18, 2026Current
Form 483s and inspection documentsNov 18, 2026Newest record Nov 17, 2026Current
Import refusalsNov 22, 2026Newest record Nov 12, 2026Current

Reviewing BIOMET UK LTD. as a supplier? Request a free FDA snapshot: name up to five suppliers and get a PDF of their public FDA record, with sources and dates. You do not need an API connection. Each snapshot is prepared by hand.

Check this supplier

Or check BIOMET UK LTD. yourself in Claude, Cursor or ChatGPT: get the full FDA risk summary, with inspections, warning letters, Form 483s and import alerts by site.

Get a free API key

Facility details

Company
Biomet UK Ltd.
Location
BRIDGEND (GB)
Source
device

Sources: openFDA, FDA Data Dashboard, FDA.gov. Report a data issue: hello@regdatalab.com.