Corin Limited — FDA Facility Profile

FEI 3002806725

Corin Limited is an FDA-registered facility (FEI 3002806725) located in CIRENCESTER Gloucestershire, GB. RegDataLab tracks 6 FDA inspections and 1 compliance action at this facility.

Reviewing Corin Limited as a supplier? Request a free FDA snapshot: name up to five suppliers and get a PDF of their public FDA record, with sources and dates. You do not need an API connection. Each snapshot is prepared by hand.

Check this supplier

Or check Corin Limited yourself in Claude, Cursor or ChatGPT: get the full FDA risk summary, with inspections, warning letters, Form 483s and import alerts by site.

Get a free API key

What FDA found at this site

Latest inspection
Oct 27, 2022: No Action Indicated (NAI)
Inspections on record
6 (1 OAI, 2 VAI, 3 NAI)
Last OAI inspection
Mar 5, 2015
Warning letters
1 listed by FDA for this FEI, latest Sep 14, 2015
Recalls as the recalling firm
10, latest Oct 2, 2026
Import refusals
10 or more

A Form 483 lists an inspector's observations. OAI means FDA recommends regulatory and/or administrative action. A warning letter is FDA's formal enforcement notice. No record here does not establish that a site is safe. Check this site on FDA's Data Dashboard.

Inspections and what FDA cited

Newest first. Citations are the inspector observations FDA publishes for the inspection.

DateResultWhat FDA cited
Oct 27, 2022No Action Indicated (NAI)No citations listed
Sep 12, 2019Voluntary Action Indicated (VAI)Lack of or inadequate complaint procedures (21 CFR 820.198(a))
Design input - Lack of or inadequate procedures (21 CFR 820.30(c))
Design verification - output does not meet input requirement (21 CFR 820.30(f))
Documentation (21 CFR 820.75(a))
and 5 more
Aug 18, 2016No Action Indicated (NAI)No citations listed
Mar 5, 2015Official Action Indicated (OAI)Design verification - Lack of or inadequate procedures (21 CFR 820.30(f))
Lack of or inadequate final acceptance procedures (21 CFR 820.80(d))
Documentation (21 CFR 820.80(e))
Lack of or inadequate procedures (21 CFR 820.100(a))
and 3 more
Nov 3, 2011No Action Indicated (NAI)No citations listed
Oct 30, 2008Voluntary Action Indicated (VAI)Process changes - review, evaluation and revalidation (21 CFR 820.75(c))
Documentation (21 CFR 820.100(b))
Justification for not reporting (21 CFR 806.20(b)(4))
Individual Report of Malfunction (21 CFR 803.50(a)(2))

Recalls

Newest first. Recalls FDA's Enforcement Report lists with this FEI as the recalling firm. The recalling firm is not always the site that made the product. Search FDA's Enforcement Report by recall number.

DateClassRecallProduct and reason
Oct 2, 2026Class IIZ-0356-2027Unity Knee ASC Modular Handle included in the Corin UNITY ASC INSTRUMENT SYSTEM. Part…
Potential malfunction of the Modular Handles where the locking mechanism may fail. Any mating instruments already engaged to the handle will…
May 23, 2025Class IIZ-2069-2025Apex Knee System. Model Numbers: KC-50090, KC-50097, KC-50110, KC-50117, KC-50130…
Investigation has identified that the age of the nylon packaging material has caused a loss of integrity of some pouches.
Oct 13, 2023Class IIZ-0213-2024Unity CR Femur Right, Size 6, Model Number 112.001.32 Primary and revision total knee… and 1 more product
Potential for Unity CR Inserts Right size 6 from batch 529803 to be incorrectly labelled as Unity CR Inserts Right size 7 from batch 532405…
Nov 8, 2022Class IIZ-0726-2023Corin BIOLOX DELTA MOD HEAD,032mm, EX LONG +7mm, REF 104.3215 and 1 more product
The BIOLOX Delta Ceramic Head size 36XL is labelled as the size 32XL and vice-versa.
Oct 31, 2022Class IIZ-0273-2023Unity Total Knee System. Used for knee prosthesis in total knee replacement
The internal packaging system for devices may have damage to the blisters potentially damaging the device or compromising the sterility of…
Jul 22, 2022Class IIZ-1509-2022Corin METAFIX HIP STEM, SIZE 3, STANDARD, 135 degrees, COLLARED HIP STEM, CEMENTLESS…
One MetaFix size 7 collarless stem from batch 478179 which was incorrectly labelled as a MetaFix size 3 collared stem from batch 485630.
Jul 12, 2022Class IIZ-1667-2022TaperFit Stem, Size 0, 38mm OFFSET, 12/14 Taper + 188.550 Centraliser, For Cemented Use…
Some of the devices did not pass fatigue testing.
Jul 28, 2021Class IIZ-2603-2021Corin TriFit TS, Size 8, Standard Tapered Stem, REF 694.0008, Sterile. and 9 more products
The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or…
May 6, 2021Class IIZ-1850-2021Corin TriIFit TS SIZE 2, STANDARD TAPERED STEM, CEMENTLESS, REF 694.0002. Hip prosthesis… and 1 more product
Units from one batch of TriFit TS size 2 stem were found to be labeled as a TriFit CF size 7 stem. And vice versa.
Jan 25, 2021Class IIZ-1290-2021Corin BIOLOX DELTA MOD HEAD 32mm EX LONG +7mm 12/14 TAPER. Corin Trinity Acetabular System… and 1 more product
The size indicated on the labeling on the outer packaging, on the inner packaging, and on the patient stickers inside the packaging is…

Facility details

Company
CORIN MEDICAL, LTD.
Location
CIRENCESTER Gloucestershire (GB)
Source
device

Sources: openFDA, FDA Data Dashboard, FDA.gov. Report a data issue: hello@regdatalab.com.