IMACOR, Inc FDA Inspection Record
IMACOR, Inc is an FDA-registered facility (FEI 3006382185) located in Jericho, NY, US. RegDataLab tracks 6 FDA inspections at this facility.
What FDA found at this site
- Latest inspection
- Oct 19, 2023: No Action Indicated (NAI)
- Inspections on record
- 6 (1 VAI, 5 NAI)
- Last OAI inspection
- None on record
- Warning letters
- None matched to this FEI. Many letters do not state an FEI: search warning letters by company name
- Recalls as the recalling firm
- 2, latest Aug 29, 2025
Inspections and what FDA cited
| Date | Result | What FDA cited |
|---|---|---|
| Oct 19, 2023 | No Action Indicated (NAI) | No citations listed |
| Jun 10, 2021 | Voluntary Action Indicated (VAI) | Complaints (21 CFR 820.198(a)) Document review, approval documentation (21 CFR 820.40(a)) Lack of Written MDR Procedures (21 CFR 803.17) |
| Mar 26, 2019 | No Action Indicated (NAI) | No citations listed |
| Nov 23, 2015 | No Action Indicated (NAI) | No citations listed |
| May 24, 2013 | No Action Indicated (NAI) | No citations listed |
| Jun 2, 2011 | No Action Indicated (NAI) | No citations listed |
Recalls
| Date | Class | Recall | Product and reason |
|---|---|---|---|
| Aug 29, 2025 | Class II | Z-0038-2026 | ClariTEE Miniaturized TEE probe. Model Number: CLT-010.
Ultrasound miniaturized TEE… Production assembly error resulting in the potential for reversed articulation, where moving the lever forward caused the probe tip to… |
| Sep 16, 2024 | Class II | Z-0231-2025 | ClariTEE Probe- Miniature transesophageal echo ultrasound probe for use with ImaCor… Epoxy used to seal the edge of the transducer into its paddle exceeded specification. This variability could attenuate the ultrasound signal… |
FDA record score
8 of 100. A count of this site's adverse public FDA records, weighted by how recent each one is. A higher number means more, or more recent, records. Each record below adds the points shown.
3 records behind this number
| Record | Date | Points x age weight | Adds |
|---|---|---|---|
| Class II recall Z-0038-2026, this FEI as the recalling firm | Aug 29, 2025 | 4 x 1 | 4 |
| Class II recall Z-0231-2025, this FEI as the recalling firm | Sep 16, 2024 | 4 x 0.6 | 2.4 |
| Inspection classified VAI | Jun 10, 2021 | 6 x 0.25 | 1.5 |
When each source was last refreshed
| Records | Last refreshed | Source as of | Status |
|---|---|---|---|
| Inspections | Nov 26, 2026 | Newest record Nov 20, 2026 | Current |
| Inspection citations | Nov 26, 2026 | Newest record Nov 17, 2026 | Current |
| Compliance actions (warning letters, injunctions and other action types) | Nov 26, 2026 | Newest record Nov 19, 2026 | Current |
| Warning letter text | Nov 24, 2026 | Newest record Nov 17, 2026 | Current |
| Recalls (Enforcement Report) | Nov 26, 2026 | Newest record Nov 25, 2026 | Current |
| Form 483s and inspection documents | Nov 18, 2026 | Newest record Nov 17, 2026 | Current |
| Import refusals | Nov 22, 2026 | Newest record Nov 12, 2026 | Current |
Reviewing IMACOR, Inc as a supplier? Request a free FDA snapshot: name up to five suppliers and get a PDF of their public FDA record, with sources and dates. You do not need an API connection. Each snapshot is prepared by hand.
Or check IMACOR, Inc yourself in Claude, Cursor or ChatGPT: get the full FDA risk summary, with inspections, warning letters, Form 483s and import alerts by site.
Facility details
- Company
- ImaCor Inc.
- Location
- Jericho, NY (US)
- Source
- device