Extremity Medical, LLC FDA Inspection Record
Extremity Medical, LLC is an FDA-registered facility (FEI 3007289093) located in Parsippany, NJ, US. RegDataLab tracks 6 FDA inspections and 1 compliance action at this facility.
What FDA found at this site
- Latest inspection
- Jun 12, 2026: No Action Indicated (NAI)
- Inspections on record
- 6 (1 OAI, 1 VAI, 4 NAI)
- Last OAI inspection
- Oct 24, 2011
- Warning letters
- 1 listed by FDA for this FEI, latest Feb 24, 2012
- Recalls as the recalling firm
- 4, latest Jan 10, 2013
Inspections and what FDA cited
| Date | Result | What FDA cited |
|---|---|---|
| Jun 12, 2026 | No Action Indicated (NAI) | No citations listed |
| May 20, 2024 | No Action Indicated (NAI) | No citations listed |
| Oct 17, 2019 | No Action Indicated (NAI) | No citations listed |
| May 24, 2016 | No Action Indicated (NAI) | No citations listed |
| Oct 9, 2012 | Voluntary Action Indicated (VAI) | Lack of or inadequate DHR procedures (21 CFR 820.184) Report of risk to health (21 CFR 806.10(a)(1)) |
| Oct 24, 2011 | Official Action Indicated (OAI) | Design changes - Lack of or Inadequate Procedures (21 CFR 820.30(i)) Nonconforming product control (21 CFR 820.90(a)) Lack of or inadequate procedures (21 CFR 820.100(a)) Investigation of device failures (21 CFR 820.198(c)) and 2 more |
Recalls
| Date | Class | Recall | Product and reason |
|---|---|---|---|
| Jan 10, 2013 | Class II | Z-0952-2013 | Extremity Medical - Disposable Orthopedic Surgical Instrument - 1.6 mm Guidewire… The 1.6 mm Guidewire is undersized up to 2 mm in length. When used with the depth gauge, the measurement reading will not correspond with… |
| Mar 22, 2012 | Class II | Z-0752-2013 | Extremity Medical, IO FiX System Accessory. Catalog Number 101-00010.
This screw… Lag screw measurement is short (approximately 5 mm) when using current screw measuring device (p/n 101-00010) per the IO FIX Surgical… |
| Apr 25, 2011 | Class II | Z-0438-2013 | IO FiX X-Post Reamer, Extremity Medical, www.extremitymedical.com; Customer Service… Product Event Reports revealed a broken reamer experienced intra-operatively. Pre-drilling was not performed prior to reaming. |
| Apr 13, 2011 | Class II | Z-0344-2013 | IO Fix IntraOsseous Fixation System; Extremity Medical. www.extremitymedical.com… Product Event Reports revealed that lag screw passes through washer (e.g. X-Post) intra-operatively. |
FDA record score
0 of 100. A count of this site's adverse public FDA records, weighted by how recent each one is. A higher number means more, or more recent, records. Each record below adds the points shown.
7 records behind this number
| Record | Date | Points x age weight | Adds |
|---|---|---|---|
| Class II recall Z-0952-2013, this FEI as the recalling firm | Jan 10, 2013 | 10 years or older, so it adds no points | 0 |
| Inspection classified VAI | Oct 9, 2012 | 10 years or older, so it adds no points | 0 |
| Class II recall Z-0752-2013, this FEI as the recalling firm | Mar 22, 2012 | 10 years or older, so it adds no points | 0 |
| Warning letter on FDA's dashboard, which does not show close-outs | Feb 24, 2012 | 10 years or older, so it adds no points | 0 |
| Inspection classified OAI | Oct 24, 2011 | 10 years or older, so it adds no points | 0 |
| Class II recall Z-0438-2013, this FEI as the recalling firm | Apr 25, 2011 | 10 years or older, so it adds no points | 0 |
| Class II recall Z-0344-2013, this FEI as the recalling firm | Apr 13, 2011 | 10 years or older, so it adds no points | 0 |
When each source was last refreshed
| Records | Last refreshed | Source as of | Status |
|---|---|---|---|
| Inspections | Nov 16, 2026 | Newest record Nov 5, 2026 | Current |
| Inspection citations | Nov 16, 2026 | Newest record Nov 5, 2026 | Current |
| Compliance actions (warning letters, injunctions and other action types) | Nov 2, 2026 | Newest record Oct 29, 2026 | Current |
| Warning letter text | Nov 16, 2026 | Newest record Nov 10, 2026 | Current |
| Recalls (Enforcement Report) | Nov 16, 2026 | Newest record Nov 11, 2026 | Current |
| Form 483s and inspection documents | Nov 13, 2026 | Newest record Nov 12, 2026 | Current |
| Import refusals | Nov 15, 2026 | Newest record Nov 5, 2026 | Current |
Reviewing Extremity Medical, LLC as a supplier? Request a free FDA snapshot: name up to five suppliers and get a PDF of their public FDA record, with sources and dates. You do not need an API connection. Each snapshot is prepared by hand.
Or check Extremity Medical, LLC yourself in Claude, Cursor or ChatGPT: get the full FDA risk summary, with inspections, warning letters, Form 483s and import alerts by site.
Facility details
- Company
- Extremity Medical, LLC
- Location
- Parsippany, NJ (US)
- Source
- device