BREAS MEDICAL, INC. FDA Inspection Record

FEI 3010817335 · Inspections, Form 483s, warning letters and import refusals

BREAS MEDICAL, INC. is an FDA-registered facility (FEI 3010817335) located in N Billerica, MA, US. RegDataLab tracks 4 FDA inspections at this facility.

What FDA found at this site

Latest inspection
Jan 18, 2022: No Action Indicated (NAI)
Inspections on record
4 (3 VAI, 1 NAI)
Last OAI inspection
None on record
Warning letters
None matched to this FEI. Many letters do not state an FEI: search warning letters by company name
Recalls as the recalling firm
5, latest Jul 25, 2024

A Form 483 lists an inspector's observations. OAI means FDA recommends regulatory and/or administrative action. A warning letter is FDA's formal enforcement notice. No record here does not establish that a site is safe. Check this site on FDA's Data Dashboard.

Inspections and what FDA cited

Newest first. Citations are the inspector observations FDA publishes for the inspection.

DateResultWhat FDA cited
Jan 18, 2022No Action Indicated (NAI)Environmental control Lack of or inadequate procedures (21 CFR 820.70(c))
Feb 6, 2020Voluntary Action Indicated (VAI)DHR - not or inadequately maintained (21 CFR 820.184)
Lack of or inadequate complaint procedures (21 CFR 820.198(a))
Nov 25, 2015Voluntary Action Indicated (VAI)Lack of or inadequate complaint procedures (21 CFR 820.198(a))
Lack of or inadequate procedures (21 CFR 820.100(a))
Purchasing controls, Lack of or inadequate procedures (21 CFR 820.50)
Oct 2, 2015Voluntary Action Indicated (VAI)Lack of or inadequate procedures (21 CFR 820.100(a))
Purchasing controls, Lack of or inadequate procedures (21 CFR 820.50)

Recalls

Newest first. Recalls FDA's Enforcement Report lists with this FEI as the recalling firm. The recalling firm is not always the site that made the product. Search FDA's Enforcement Report by recall number.

DateClassRecallProduct and reason
Jul 25, 2024Class IZ-2690-2024Vivo 45 LS, pressure and volume ventilator capable of delivering continuous or…
There is a potential for short term (<7 days) elevated levels of formaldehyde emitted from the device into the patient breathing airpath in…
Oct 13, 2023Class IIZ-0405-2024with Notch 22M/15F sold as part of Breas Medical MPV circuit 2 pc Kits: 006093, 006653…
Produced with unintended open slits on the side of the mouthpiece body, may result in insufficient ventilation in spontaneous breathing…
Jun 2, 2022Class IIZ-1382-2022Vivo 45LS Ventilator- intended to provide continuous or intermittent ventilatory support…
A forced shutdown of one of the processors did not generate a watch dog alarm, would develop into a failure AND the instructions to monitor…
Mar 21, 2022Class IIZ-0943-2022Breas Ventilator Trolley with the Vivo 50/60/65 and Vivo 45LS ventilator models Article…
Ventilator mounting brackets for the Vivo 50/60/65 and Vivo 45LS ventilator models can become detached from the Breas Ventilator Trolley…
Jan 28, 2020Class IIZ-1352-2020Protective Cover Vivo 55/65 (Used for Vivo 50/65), Part No. 006344. It is an accessory…
The outlet hole of the exhalation valve control pressure tube on the ventilator may become obstructed by the protective cover.

FDA record score

19 of 100. A count of this site's adverse public FDA records, weighted by how recent each one is. A higher number means more, or more recent, records. Each record below adds the points shown.

Counted on Nov 25, 2026, method version 1. It counts records and does not judge the site: a low number does not establish that a site is safe, and sites that FDA inspects more often can collect more points. How this is counted.

8 records behind this number
RecordDatePoints x age weightAdds
Class I recall Z-2690-2024, this FEI as the recalling firmJul 25, 202415 x 0.69
Class II recall Z-0405-2024, this FEI as the recalling firmOct 13, 20234 x 0.62.4
Class II recall Z-1382-2022, this FEI as the recalling firmJun 2, 20224 x 0.62.4
Class II recall Z-0943-2022, this FEI as the recalling firmMar 21, 20224 x 0.62.4
Inspection classified VAIFeb 6, 20206 x 0.251.5
Class II recall Z-1352-2020, this FEI as the recalling firmJan 28, 20204 x 0.251
Inspection classified VAINov 25, 201510 years or older, so it adds no points0
Inspection classified VAIOct 2, 201510 years or older, so it adds no points0

When each source was last refreshed

FDA sources behind this page and when RegDataLab last refreshed each one
RecordsLast refreshedSource as ofStatus
InspectionsNov 25, 2026Newest record Nov 20, 2026Current
Inspection citationsNov 25, 2026Newest record Nov 17, 2026Current
Compliance actions (warning letters, injunctions and other action types)Nov 25, 2026Newest record Nov 19, 2026Current
Warning letter textNov 24, 2026Newest record Nov 17, 2026Current
Recalls (Enforcement Report)Nov 25, 2026Newest record Nov 25, 2026Current
Form 483s and inspection documentsNov 18, 2026Newest record Nov 17, 2026Current
Import refusalsNov 22, 2026Newest record Nov 12, 2026Current

Reviewing BREAS MEDICAL, INC. as a supplier? Request a free FDA snapshot: name up to five suppliers and get a PDF of their public FDA record, with sources and dates. You do not need an API connection. Each snapshot is prepared by hand.

Check this supplier

Or check BREAS MEDICAL, INC. yourself in Claude, Cursor or ChatGPT: get the full FDA risk summary, with inspections, warning letters, Form 483s and import alerts by site.

Get a free API key

Facility details

Company
Human Design Medical, LLC
Location
N Billerica, MA (US)
Source
device

Sources: openFDA, FDA Data Dashboard, FDA.gov. Report a data issue: hello@regdatalab.com.