Z-0675-2025 Class II Ongoing
Recall Details
- Product Type
- Devices
- Report Date
- December 18, 2024
- Initiation Date
- November 1, 2024
- Termination Date
- N/A
- Voluntary/Mandated
- Voluntary: Firm initiated
- Product Quantity
- 940,203 total units
Product Description
Cardinal Health SMS Elastic Cuff Thumbhook Level 3 Isolation Gown, Full-Back, Product Codes AT6588-2XL, AT6588-BD, AT6588-XL, AT6688-2XL, AT6688-BD, and AT6688-XL
Reason for Recall
Isolation Gowns were manufactured with raw materials that may fail the hydrostatic pressure specification and therefore would not comply with AAMI (The Association for the Advancement of Medical Instrumentation) Level 3 protection requirements.
Distribution Pattern
US Nationwide. Canada, UAE
Code Information
All lots. AT6588-2XL UDI-DI: CS (01) 50885380166639 EA (01) 20885380166638; AT6588-BD UDI-DI: CS (01) 50885380166646 EA (01) 20885380166645; AT6588-XL UDI-DI: CS (01) 50885380166653 EA (01) 20885380166652; AT6688-2XL UDI-DI: CS (01) 50885380166660 EA (01) 20885380166669; AT6688-BD UDI-DI: CS (01) 50885380166677 EA (01) 20885380166676; AT6688-XL UDI-DI: CS (01) 50885380166684 EA (01) 20885380166683