Z-0866-2019 Class II Terminated
Recalled by Zimmer Biomet Spine Inc.
— Westminster, CO
FDA device recall Z-0866-2019 was initiated by Zimmer Biomet Spine Inc. on Jul 30, 2018 and is designated Class II. Reason for recall: The Vitality Shear-off Set Screw is not threading properly with the mating tulip head of the Vitality screws, hooks and connectors due to a manufacturing issue.These devices are indicated as an… The recall status is terminated (terminated Apr 28, 2021). Affected quantity: 16,429 devices (Thoracolumbosacral pedicle screw system,Spinal Interlaminal & Spinal Intervertebral Body, both…
Recall details
- Product Type
- Devices
- Report Date
- Mar 6, 2019
- Initiation Date
- Jul 30, 2018
- Termination Date
- Apr 28, 2021
- Voluntary/Mandated
- Voluntary: Firm initiated
- Product Quantity
- 16,429 devices (Thoracolumbosacral pedicle screw system,Spinal Interlaminal & Spinal Intervertebral Body, both appliances for fixation)
Product description
Vitality¿ Spinal Fixation System. Thoracolumbosacral pedicle screw system (non-sterile). Pedicle screw fixation is indicated for skeletally mature patients and for adolescent patients. For use in Orthopedic medical specialty area. Product Usage: The Vitality Shear-off Set Screw is not threading properly with the mating tulip head of the Vitality screws, hooks and connectors due to a manufacturing issue. These devices are indicated as an adjunct to fusion for various indications
Reason for recall
The Vitality Shear-off Set Screw is not threading properly with the mating tulip head of the Vitality screws, hooks and connectors due to a manufacturing issue.These devices are indicated as an adjunct to fusion for various indications
Distribution pattern
Distributed Nationwide: AL, CA, CO, FL, GA, HI, IA, ID, IL, IN, LA, MA, MD, MI, MN, NC, NJ, NV, NY, OH, OK, PA, SC, TN, TX, WA and WI.**** International distribution: Australia and EMEA.
Code information
Item Number; Lot Number; Item Description; UDI #; Manufacturing Quantity 07.02011.001; P141352 (Z00176603); Vitality Shear-off Set Screw; (01)00889024003187 (10)P141352; 2,192 devices 07.02011.001; P141353; Vitality Shear-off Set Screw; (01)00889024003187 (10)P141353; 879 devices 07.02011.001; P141354 (Z00468651); Vitality Shear-off Set Screw; (01) 00889024003187 (10)P141354; 924 devices 07.02011.001; P141358 (Z00420148); Vitality Shear-off Set Screw; (01)00889024003187 (10)P141358; 2,193 devices 07.02011.001; P141359 (Z00274115); Vitality Shear-off Set Screw; (01)00889024003187 (10)P141359; 868 devices 07.02011.001; P141360; Vitality Shear-off Set Screw; (01)00889024003187 (10)P141360; 872 devices 07.02011.001; P142510; Vitality Shear-off Set Screw; (01)00889024003187 (10)P142510; 3,045 devices 07.02011.001; W505611; Vitality Shear-off Set Screw; (01)00889024003187 (10)W505611; 1,545 devices 07.02011.001; W508041; Vitality Shear-off Set Screw; (01)00889024003187 (10)W508041; 1,497 devices 07.02011.001; W509651; Vitality Shear-off Set Screw; (01)00889024003187 (10)W509651; 3,396 devices 07.02011.001; W509661; Vitality Shear-off Set Screw; (01)00889024003187 (10)W509661; 3,382 devices 07.02011.001; W5096619; Vitality Shear-off Set Screw; (01)00889024003187 (10)W5096619; 61 devices 07.02011.001; W526991; Vitality Shear-off Set Screw; (01)00889024003187 (10)W526991; 799 devices 07.02011.001; W529371; Vitality Shear-off Set Screw; (01)00889024003187 (10)W529371; 823 devices 07.02011.001; W530301; Vitality Shear-off Set Screw; (01)00889024003187 (10)W530301; 1,342 devices 07.02011.001; W546001; Vitality Shear-off Set Screw; (01)00889024003187 (10)W546001; 634 devices 07.02011.001; W554821; Vitality Shear-off Set Screw; (01)00889024003187 (10)W554821; 2,110 devices 07.02011.001; W559871; Vitality Shear-off Set Screw; (01)00889024003187 (10)W559871; 1,461 devices 07.02011.001; W573501; Vitality Shear-off Set Screw; (01)00889024003187 (10)W573501; 2,713 devices 07.02011.001; W573511; Vitality Shear-off Set Screw; (01)00889024003187 (10)W573511; 2,698 devices 07.02011.001; W577991; Vitality Shear-off Set Screw; (01)00889024003187 (10)W577991; 2,026 devices
Source
- Dataset
- openFDA device recall enforcement reports
- FDA record
- This recall in openFDA (JSON)
- Enforcement Report
- Search FDA's Enforcement Report for Z-0866-2019
- openFDA file date
- Nov 25, 2026
- Loaded by RegDataLab
- Nov 26, 2026
These dates say when openFDA published the data file and when RegDataLab last loaded it.