Z-0898-2017 Class II Terminated

Recalled by Teleflex Medical — Research Triangle Park, NC

FDA device recall Z-0898-2017 was initiated by Teleflex Medical on Oct 27, 2016 and is designated Class II. Reason for recall: Product Defect; These products may produce a straight stream instead of a fully atomized plume of medication. The recall status is terminated (terminated Sep 25, 2020). Affected quantity: 2,674,650 units in total.

Recall details

Product Type
Devices
Report Date
Dec 28, 2016
Initiation Date
Oct 27, 2016
Termination Date
Sep 25, 2020
Voluntary/Mandated
Voluntary: Firm initiated
Product Quantity
2,674,650 units in total

Product description

Mucosal Atomization Device (MAD), Intranasal Mucosal Atomization Device with 3mL Syringe and Vial Adapter; Product Code MAD100, MAD100OS MAD110, MAD110OS, MAD130, MAD130OS, MAD140, MAD140OS, MAD300, MAD300B. Manufactured By: Wolfe-Tory Medical, Inc., Teleflex Medical. For atomization of topical solutions across the naso and oropharyngeal mucosal membranes

Reason for recall

Product Defect; These products may produce a straight stream instead of a fully atomized plume of medication.

Distribution pattern

Worldwide distribution. U.S. (Nationwide) and Internationally to Canada, Belgium, Singapore and Thailand.

Code information

Product code MAD100, Batch/Lot numbers 160105, 160137, 160302, 160321, 160402, 160435, 160506, 160523, 160609, 160620, 160707, 160802, 160813; Product code MAD100OS, Batch/Lot numbers 160322, 160524, 160630; Product code MAD110, Batch/Lot numbers 160217, 160507; Product code MAD110OS, Batch/Lot numbers 160240, 160312; Product code MAD130, Batch/Lot numbers 160107, 160138, 160517; Product code MAD130OS, Batch/Lot numbers 160436, 160803; Product code MAD140, Batch/Lot numbers 160125, 160218, 160437, 160610, 160801; Product code MAD140OS, Batch/Lot numbers 160226, 160438, 160727; Product code MAD300, Batch/Lot numbers 160108, 160117, 160126, 160145, 160146, 160200, 160219, 160225, 160231, 160300, 160313, 160327, 160400, 160409, 160422, 160432, 160440, 160500, 160518, 160602, 160611, 160621, 160631, 160701, 160708, 160718, 160728, 160800, 160804, 160814, 160816, 160823; Product code MAD300B, Batch/Lot number 160410.

Source

Dataset
openFDA device recall enforcement reports
FDA record
This recall in openFDA (JSON)
Enforcement Report
Search FDA's Enforcement Report for Z-0898-2017
openFDA file date
Nov 27, 2026
Loaded by RegDataLab
Nov 28, 2026

These dates say when openFDA published the data file and when RegDataLab last loaded it.

Need the full FDA record for Teleflex Medical? Ask Claude with the RegDataLab connector and get every site's inspections, Form 483s, warning letters, recalls and import alerts, each with a link to the FDA source. Free to start, no card.

Question to ask in Claude

Use RegDataLab to give me an FDA risk summary for Teleflex Medical: recent inspections and their outcomes, warning letters, recalls and import alerts by site, with source links and dates.

Ask Claude about Teleflex Medical →

Source: openFDA record for Z-0898-2017. Report a data issue: hello@regdatalab.com.