Z-2047-2016 Class II Terminated

Recalled by Ceg Enterprises Llc — Hopkins, MN

FDA device recall Z-2047-2016 was initiated by Ceg Enterprises Llc on April 5, 2016 and is designated Class II. Reason for recall: CEG Enterprises, LLC is recalling Germ Terminator Toothbrush Sanitizer GT100 due to the following issues: UL label believed to be not genuine; discoloration of power cords (could indicate some degrad… The recall status is terminated (terminated November 22, 2016). Affected quantity: 100,548 units.

Recall Details

Product Type
Devices
Report Date
June 29, 2016
Initiation Date
April 5, 2016
Termination Date
November 22, 2016
Voluntary/Mandated
Voluntary: Firm initiated
Product Quantity
100,548 units

Product Description

Germ Terminator, Toothbrush Steam Sterilization for Oral Health. Model GT100. The Germ Terminator uses steam heat to sanitize two manual toothbrushes or two toothbrush heads. Water is poured into a reservoir in the device's housing. The steam cycle is followed by a drying cycle.

Reason for Recall

CEG Enterprises, LLC is recalling Germ Terminator Toothbrush Sanitizer GT100 due to the following issues: UL label believed to be not genuine; discoloration of power cords (could indicate some degradation); reports of excessive heat.

Distribution Pattern

Nationwide Distribution through Tuesday Morning retail stores.

Code Information

Model GT100