Z-2111-2025 Class II Ongoing

Recalled by Beyond Laser Systems, LLC — Austin, TX

FDA device recall Z-2111-2025 was initiated by Beyond Laser Systems, LLC on Jun 30, 2025 and is designated Class II. Reason for recall: The remote interlock connector, which is required by 21 CFR 1040.10(f)(3), in the remote stop box was not installed the connector or was mechanically installed but not wired. The labels placed on the… The recall status is ongoing. Affected quantity: 10.

Recall details

Product Type
Devices
Report Date
Jul 23, 2025
Initiation Date
Jun 30, 2025
Voluntary/Mandated
FDA Mandated
Product Quantity
10

Product description

Laser light show projectors manufactured by BLS, Model DIODE 1000/2000/3000.

Reason for recall

The remote interlock connector, which is required by 21 CFR 1040.10(f)(3), in the remote stop box was not installed the connector or was mechanically installed but not wired. The labels placed on the projectors do not meet requirements specified in 21 CFR 1010.4 (Variances), 21 CFR 1010.2 (Certification), 21 CFR 1010.3 (Identification) and 21 CFR 1040.10 (g)(Labelling requirements). The identification label does not include the date of manufacture as required by 21 CFR 1010.3. The corrective action plan covers three families of laser light show of projectors: DIODE. CLUB and PURE with three different hardware configurations such as the number of the number of RJ45 ports, radiant power of emissions and network configurations. No specific user manuals were provided to each model family as required by 21 CFR 1040.10(h)(1) (Informational requirements (1) User information). The Quality Control test did not validate the manual reset function to enable resumption of laser radiation emission from Class IV laser projectors after an interruption caused using a remote interlock. No supplemental product reports, as required according to 21 CFR 1002.11.

Distribution pattern

US Nationwide Distribution

Code information

N/A

Source

Dataset
openFDA device recall enforcement reports
FDA record
This recall in openFDA (JSON)
Enforcement Report
Search FDA's Enforcement Report for Z-2111-2025
openFDA file date
Nov 16, 2026
Loaded by RegDataLab
Nov 17, 2026

These dates say when openFDA published the data file and when RegDataLab last loaded it.

Source: openFDA record for Z-2111-2025. Report a data issue: hello@regdatalab.com.