FDA Inspection 656129 — Gasco Industrial Corp.
The FDA completed an inspection of Gasco Industrial Corp. on Mar 31, 2010 in Gurabo, PR. The inspection was classified VAI (Voluntary Action Indicated — objectionable conditions or practices were found, but the agency is not prepared to take or recommend any administrative or regulatory action). 12 citations were issued during this inspection. Product area: Drugs.
Inspection details
- Classification
- Voluntary Action Indicated (VAI)
- End Date
- Mar 31, 2010
- Fiscal Year
- 2010
- Product Type
- Drugs
- Project Area
- Drug Quality Assurance
- Location
- Gurabo, PR (United States)
Citations
| ID | CFR | Description |
|---|---|---|
| 1215 | 21 CFR 211.67(b) | Written procedures not established/followed |
| 1227 | 21 CFR 211.67(c) | Cleaning/maintenance records not kept |
| 1274 | 21 CFR 211.68(a) | Calibration/Inspection/Checking not done |
| 1361 | 21 CFR 211.100(a) | Absence of Written Procedures |
| 1767 | 21 CFR 211.137(a) | Expiration date lacking |
| 1885 | 21 CFR 211.165(b) | Microbiological testing |
| 3582 | 21 CFR 211.105(a) | Identification of containers, lines, equipment |
| 4306 | 21 CFR 211.80(a) | Written Procedures Not Followed |
| 4307 | 21 CFR 211.80(d) | Status of Each Lot Identified |
| 4350 | 21 CFR 211.160(b)(3) | Drug products-sampling procedures/specifications |
| 4389 | 21 CFR 211.198(a) | Procedures to be written and followed |
| 9001 | 21 CFR 211.22(a) | Lack of quality control unit |