FDA Inspection 759820 — Mill Stream Corp.
The FDA completed an inspection of Mill Stream Corp. on December 20, 2011 in Hancock, ME. The inspection was classified OAI (Official Action Indicated — objectionable conditions were found and regulatory action is recommended). 10 citations were issued during this inspection. Product area: Food/Cosmetics.
Inspection Details
- Classification
- Official Action Indicated (OAI) (OAI)
- End Date
- December 20, 2011
- Fiscal Year
- 2012
- Product Type
- Food/Cosmetics
- Project Area
- Foodborne Biological Hazards
- Location
- Hancock, ME (United States)
Citations
| ID | CFR | Description |
|---|---|---|
| 1554 | 21 CFR 110.35(a) | Cleaning and sanitizing operations |
| 1565 | 21 CFR 110.35(d)(3) | Non-food-contact surfaces (S) |
| 6001 | 21 CFR 123.11(b) | Sanitation monitoring documentation |
| 6007 | 21 CFR 123.9(a) | Records entries - timing |
| 6012 | 21 CFR 123.8(a)(3)(iii) | Calibration record review adequacy |
| 6014 | 21 CFR 123.6(c)(2) | Monitoring - none |
| 6018 | 21 CFR 123.7(a) | Corrective action per predetermined plan |
| 905 | 21 CFR 123.6(b) | HACCP plan implementation |
| 959 | 21 CFR 123.6(c)(1) | Food safety hazards |
| 960 | 21 CFR 123.6(c)(2) | Critical control points |