FDA Inspection 765827 — Sensible Organics, Inc.
The FDA completed an inspection of Sensible Organics, Inc. on Feb 9, 2012 in Beaver Falls, PA. The inspection was classified VAI (Voluntary Action Indicated — objectionable conditions or practices were found, but the agency is not prepared to take or recommend any administrative or regulatory action). 15 citations were issued during this inspection. Product area: Food/Cosmetics.
Inspection details
- Classification
- Voluntary Action Indicated (VAI)
- End Date
- Feb 9, 2012
- Fiscal Year
- 2012
- Product Type
- Food/Cosmetics
- Project Area
- Colors and Cosmetics Technology
- Location
- Beaver Falls, PA (United States)
Citations
| ID | CFR | Description |
|---|---|---|
| 1049 | 21 CFR 211.22(a) | Approve or reject components, products |
| 1112 | 21 CFR 211.25(a) | Training--operations, GMPs, written procedures |
| 1134 | 21 CFR 211.25(b) | Supervisor Training/Education/Experience |
| 1393 | 21 CFR 211.103 | Yield calculations not verified by 2nd person |
| 1395 | 21 CFR 211.103 | Actual vs. theoretical yields not determined |
| 1448 | 21 CFR 211.111 | Establishment of time limitations |
| 1777 | 21 CFR 211.150(b) | Distribution Recall System |
| 1914 | 21 CFR 211.166(a) | Lack of written stability program |
| 2007 | 21 CFR 211.186(a) | Signature and checking of records -- 2 persons |
| 3592 | 21 CFR 211.110(c) | In-process materials characteristics testing |
| 4352 | 21 CFR 211.160(b)(4) | Calibration - at intervals, written program, remedial action |
| 4376 | 21 CFR 211.188(b)(4) | Weights and measures of components used |
| 4404 | 21 CFR 211.194(a)(1) | Sample identification and other information |
| 4413 | 21 CFR 211.194(a)(8) | Second person sign off |
| 4576 | 21 CFR 211.192 | No written record of investigation |