The FDA completed an inspection of Genesiscare on May 23, 2014 in Naples, FL. The inspection was classified VAI (Voluntary Action Indicated — objectionable conditions or practices were found, but the agency is not prepared to take or recommend any administrative or regulatory action). 3 citations were issued during this inspection. Product area: Biologics.

Inspection details

Classification
Voluntary Action Indicated (VAI)
End Date
May 23, 2014
Fiscal Year
2014
Product Type
Biologics
Project Area
Blood and Blood Products
Location
Naples, FL (United States)

Citations

IDCFRDescription
15921 CFR 606.160(a)(1)Legibility and indelibility
7621 CFR 606.100(b)Establish, maintain and follow manufacturing SOPs
7821 CFR 606.100(c)Record review prior to release