FDA Inspection 885209 — Hydrox Chemical Company

Hydrox Chemical Company — FEI 1419821

The FDA completed an inspection of Hydrox Chemical Company on September 4, 2014 in Elgin, IL. The inspection was classified VAI (Voluntary Action Indicated — objectionable conditions were found but do not meet the threshold for regulatory action). 9 citations were issued during this inspection. Product area: Food/Cosmetics.

Inspection Details

Classification
Voluntary Action Indicated (VAI) (VAI)
End Date
September 4, 2014
Fiscal Year
2014
Product Type
Food/Cosmetics
Project Area
Colors and Cosmetics Technology
Location
Elgin, IL (United States)

Citations

IDCFRDescription
110521 CFR 211.22(d)Procedures not in writing, fully followed
117721 CFR 211.63Equipment Design, Size and Location
121321 CFR 211.67(a)Cleaning / Sanitizing / Maintenance
136121 CFR 211.100(a)Absence of Written Procedures
139521 CFR 211.103Actual vs. theoretical yields not determined
179121 CFR 211.80(c)Storage off Floor, Spaced Suitably
197821 CFR 211.182Personnel dating/signing equipment log
358221 CFR 211.105(a)Identification of containers, lines, equipment
440221 CFR 211.192Written record of investigation incomplete