Z-0823-2020 Class II Terminated
FDA device recall Z-0823-2020 was initiated by Isopure Corp on April 19, 2019 and is designated Class II. Reason for recall: There is a potential for an uneven plastic encapsulation of the magnet ring during the molding process and partial axial displacement. This issue could cause uneven wear during use, cause exposure of … The recall status is terminated (terminated May 29, 2020). Affected quantity: 8.
Recall Details
- Product Type
- Devices
- Report Date
- January 29, 2020
- Initiation Date
- April 19, 2019
- Termination Date
- May 29, 2020
- Voluntary/Mandated
- Voluntary: Firm initiated
- Product Quantity
- 8
Product Description
Finish Thompson Centrifugal Pump Model #110192-3 (sold as spare part)
Reason for Recall
There is a potential for an uneven plastic encapsulation of the magnet ring during the molding process and partial axial displacement. This issue could cause uneven wear during use, cause exposure of the magnet to solution, and thereby result in corrosion and the presence of iron.
Distribution Pattern
The products were distributed to the following US states: AL, FL, GA, MA, MD, MN, NC, NM, NY, OH, OK, TX, and VA.
Code Information
Pump Serial Numbers: 178323B18, 178751C18, 178749C18, 180214D18, 180213D18, 180208D18, 178747C18, 178750C18